CFLQW - ISOLITE 862
- MSDS: CFLQW
- Manufacturer: SCHENECTADY INTERNATIONAL INC
- Product Name: ISOLITE 862
- National Stock Number: 6810-00N050596
Product Identification
Product ID:ISOLITE 862
MSDS Date:05/18/1995
FSC:6810
NIIN:00N050596
MSDS Number: CFLQW
Responsible Party
US
Emergency Phone: 518-370-4200
Info Phone: 518-370-4200
Cage: GO827
Contractor
Telephone: 518-370-4200
Cage: 88577
Ingredients
CLTHG, & WASH PATIENT W/SURFACTANT LIKE TINCTURE OF
RTECS: 9999999ZZ
MIN. IF THERE ARE ANY SIGNS OF SKIN SENSIT,
RTECS: 9999999ZZ
REQUIRED BY SIZE OF SPILL. DECONTAM AREA.
RTECS: 9999999ZZ
RECLAMATION/DISP. DETERMINE APPROP COURSE OF ACTION
RTECS: 9999999ZZ
ACCORDING TO GOVERNMENTAL REGULATIONS.
RTECS: 9999999ZZ
FOLLOW LABEL WARNINGS EVEN AFTER CONTAINER IS
RTECS: 9999999ZZ
PARTICLES, & BLOT, W/ABSORB MATL, ANY EXCESS LIQS
RTECS: 9999999ZZ
1,1,2-BENZENEDICARBOXYLIC ACID, DI-2-PROPENYL ESTER;
CAS: 131-17-9
RTECS: CZ4200000
Fraction By Weight: 40-50%
OSHA PEL N/K
ACGIH TLV: N/K
PEROXIDE, BIS(ALPHA, ALPHA-DIMETHYLBENZYL); (DICUMYL
CAS: 80-43-3
RTECS: SD8150000
Fraction By Weight: 1-2%
OSHA PEL N/K
ACGIH TLV: N/K
1.3 @ 20C
CAS: 50-00-0
RTECS: LP8925000
Fraction By Weight: >50%
OSHA PEL SEE 1910.1048
ACGIH TLV: C 0.3 PPM, A2
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
UPPER RESP
RTECS: 9999999ZZ
DYSPNEA, TACHYPNEA, & RALES MAY LEAD RAPIDLY TO
RTECS: 9999999ZZ
MOVE TO FRESH AIR IMMED;
RTECS: 9999999ZZ
REBREATHER MASK AT 6-12 L/MIN. IF BRTHG HAS STOPPED,
RTECS: 9999999ZZ
REST, WHILE OBTAINING MED ATTN. MONITOR FOR PULM
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE: DIALLYL PHTHALATE: HARMFUL IF
INHALED. LUNG IRRIT. MAY BE TERATOGEN. HAS TESTED POS AS MUTAGEN.
MAY AFFECT LIVER. MAY CAUSE EYE & SKIN IRRIT. MAY AFFECT MUC MEMB.
DICUMYL PEROXIDE: SENSITIZER. MAY CAUSE SKIN IRRIT. FORMALDEHYDE:
CAUSES EYE & SKIN BURNS. HARMFUL IF ABSORBED THRU SKIN. HARMFUL
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:FORMALDEHYDE: IARC MONO, VOL 62, PG 217,
1995: GROUP 2A. NTP 7TH ANNUAL RPT ON CARCINS, 1994: ANTIC TO BE
(SUP DAT)
Effects of Overexposure:HLTH HAZ: IF INHALED. LUNG IRRIT. HAS TESTED
POS AS MUTAGEN. MAY AFFECT LIVER, KIDNEYS, SENSITIZER. MAY CAUSE
RESP SENSIT, NERV SYS EFTS. MAY CAUSE BLOOD CHEMISTRY CHANGES. MAY
AFFECT MUC MEMB. MAY CA USE ALLERGIC RXN. SYMPS: CARDIOVASCULAR:
CARD ARRHYS; TACHYCARDIA; & HYPOTENSION MAY BE PRESENT. CNS: CNS
(SUP DAT)
Medical Cond Aggravated by Exposure:ANY PREEXISTING ABNORMAL CONDITIONS
OF SKIN, EYES, LUNGS, RESPIRATORY SYSTEM.
First Aid
First Aid:EYES: FLUSH IMMED FOR AS LONG AS 15 MIN W/LGE AMTS OF
WATER/NORM SALINE SOLN; LIFTING LOWER & UPPER LIDS OCCAS/IF APPROP,
USE EYE IRRIGATION LENS. IF THERE ARE ANY SIGNS OF EYE IRRIT/CHEM
BURNS, OBTAI N PROMPT MED ATTN. INGEST: ADMIN 4-8 OZOF WATER FOR
DILUTION IF PROD WAS INGESTED & PATIENT CAN SWALLOW, HAS GOOD GAG
REFLEX, & NO DROOLING. DO NOT USE EMESIS. NEVER GIVE ANYTHING TO AN
UNCON (ING 6)
Fire Fighting
Flash Point:>329F,>165C
Extinguishing Media:CARBON DIOXIDE, DRY, FOAM, FOG.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . EXCLUDE AIR; TREAT LIKE A GASOLINE OR OIL FIRE.
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION IT MAY EMIT
TOXIC FUMES. MAY SELF-REACT OR IGNITE.
Accidental Release
Spill Release Procedures:STOP SOURCE OF SPILL & REMOVE ALL IGNIT
SOURCES. VENT AREA OF SPILL. CONTAIN SPILL & PVNT MATL FROM
OBTAINING ACCESS TO ANY CONFINED SPACES, PUBLIC SEWERS/WATERWAYS.
COLLECT MATL USING ABSORBS, NON-SP KG TOOLS, EXPLO-PROOF
VACUUMS/OTHER EQUIP (ING 12)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID CONT W/EYES, SKIN/CLTHG. AVOID
BRTHG VAPS, DUST/FUMES. KEEP CONTR TIGHTLY CLOSED. USE W/ADEQ VENT.
KEEP FROM CONT OTHER COMBUST MATLS.
Other Precautions:PROT CONTR FROM PHYSICAL ABUSE. STORE OUTSIDE/IN
APPROP DETACHED CHEM STOR AREA. STORE IN COOL, DRY, WELL-VENTD FLAM
STOR AREA AWAY FROM IGNIT SOURCES. KEEP SEPARATE FROM
INCOMPATIBLES. SINCE EMPTIED CONTRS MAY RETAIN MATL RESIDUE, (ING
15)
Exposure Controls
Respiratory Protection:RESPIRATION EQUIPMENT NEEDED IF CITED TLV LIMITS
ARE EXCEEDED. USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:MAINTAIN VAPOR LEVELS BELOW CITED TLV OR EXPLOSION LIMITS
FOR MENTIONED HAZARDOUS MATERIALS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WEAR APPROPRIATE, CLEAN, PROTECTIVE CLOTHING
AND KEEP CONTACT (BODY) AREAS CLEAN.
Supplemental Safety and Health
EXPLAN OF CARCIN: CARCIN. OSHA REGULATED: CFR 29 1910.1048. ANIMAL:
NASAL TUMORS. EFTS OF OVEREXP: DEPRESS TO COMA. CONFUSION,
DISORIENTATION, HDCH, DROW, WEAK, & SEIZURES MAY BE PRESENT. EYE:
CHEM CO NJ. GI: MUC MEMB PAIN & IRRIT; NAUS; VOMIT & DIARR. LIFE:
CNS DEPRESS MAY LEAD TO RESP ARREST. CONVLS, CARD (ING 4)
Chemical Properties
Vapor Pres:SEE INGS
Vapor Density:>AIR
Spec Gravity:1.170-1.190
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:CLEAR AMBER LIQUID WITH A CHARACTERISTIC ODOR OF
DIALLYL PHTHALATE
Stability
Stability Indicator/Materials to Avoid:YES
AVOID STRONG OXIDANTS. CONTACT NEHC FOR MORE SPECIFIC INFORMATION .
Stability Condition to Avoid:AVOID ANY HEAT, SPARKS OR STATIC
ELECTRICITY.
Hazardous Decomposition Products:ON THERMAL DECOMPOSITION IT MAY EMIT
TOXIC FUMES, INCLUDING CARBON MONOXIDE AND/OR CARBON DIOXIDE.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.